Dynatech Elevation
VEGA HS
Overspeed Governor VEGA HS
Acting: BI-DIRECTIONAL or SINGLE-ACTING

Maximum rated speed: 3,4 m/s
Minimum rated speed: 2,3 m/s

Tripping speed:
  • BI-DIRECTIONAL or SINGLE-ACTING:
    Minimum: 2,8 m/s ; Maximum: 4,2 m/s

Pulley Diameter: 200 mm
Rope Diameter: 6 mm / 6,3 mm / 6,5 mm
Overspeed contact included
Rope out protection included

Remote reset by Electrical Acting: 24, 48 or 190 VDC (optional).
 
  • ​(Optional) Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC
 
  • (Optional) Anticreep device by electrical acting: 24, 48 or 190 VDC + Inductive Sensor (Included). When using the SD-BOX electronic device for UCM with Anticreep system for UCM, COIL should be 24VDC

NB. For optimal performance, it is highly recommended to use the anti-creep system in conjunction with the SD-BOX.


230 VAC - 190 VDC Rectifier (optional)
Protection plate (optional) - Hardened groove (optional)

* It is recommended to use a hardened groove for long travels or high speeds; especially for bidirectional overspeed governors.

According to the standards: 
EN 81-20 and EN 81-50.

Operating and maintenance instructions
Dynatech
Poligono Ind. de Pina de Ebro. Sector C.p-9. 50750 Pina de Ebro. Zaragoza-España(Spain)
© 2005 -2023 Dynatech Legal Aspects