Dynatech Elevation
VEGA PLUS
Overspeed Governor VEGA PLUS
Acting: BI-DIRECTIONAL or SINGLE-ACTING

Maximum rated speed: 2,4 m/s
Minimum rated speed: 0,1 m/s

Tripping speed:
  • BI-DIRECTIONAL or SINGLE-ACTING:
    Minimum: 0,7 m/s ; Maximum: 2,87 m/s
     
  • ONLY SINGLE-ACTING (VEGA PLUS LS):
    Minimum: 0,4 m/s ; Maximum: 0,7 m/s
     
Pulley Diameter: 200 mm
Rope Diameter: 6 mm / 6,3 mm / 6,5 mm
Overspeed contact included
Rope out protection included
  • Remote reset by Safety Switch up to 1 m/s of rated speed included.
  • Remote reset by Electrical Acting: 24, 48 or 190 VDC starting from 1 m/s of rated speed (optional)
     
  • (Optional) Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC 
 
  • ​(Optional) Anticreep device by electrical acting: 24, 48 or 190 VDC + Inductive Sensor (Included). When using the SD-BOX electronic device for UCM with Anticreep system for UCM, COIL should be 24VDC

NB. For optimal performance, it is highly recommended to use the anti-creep system in conjunction with the SD-BOX.


Ready for encoder positioning - Encoder (optional)
230 VAC - 190 VDC Rectifier (optional)
Protection plate (optional)
Hardened groove (optional)

VEGA PLUS overspeed governor adaptable to Category 2 seismic conditions (optional) click here

According to the standards: 
EN 81-20, 
EN 81-50 and EN 81-77.
Operating and maintenance instructions
Certificate TP TC 011/2011
Dynatech
Poligono Ind. de Pina de Ebro. Sector C.p-9. 50750 Pina de Ebro. Zaragoza-España(Spain)
© 2005 -2023 Dynatech Legal Aspects