VEGA 300
Overspeed Governor VEGA 300
Acting: BI-DIRECTIONAL or SINGLE-ACTING
Maximum rated speed: 3,4 m/s
Minimum rated speed: 0,1 m/s
Tripping speed:
- BI-DIRECTIONAL or SINGLE-ACTING:
Minimum: 0,8 m/s ; Maximum: 4,2 m/s
- ONLY SINGLE-ACTING (VEGA 300 LS):
Minimum: 0,5 m/s ; Maximum: 0,8 m/s
Pulley Diameter: 300 mm
Rope Diameter: 6 mm / 6,5 mm
Overspeed contact included
Rope out protection included
Hardened groove as standard (for rated speeds greater than 2 m/s)
- Remote reset by Safety Switch up to 1 m/s of rated speed included.
- Remote reset by Electrical Acting: 24, 48 or 190 VDC starting from 1 m/s of rated speed (optional).
- (Optional) Remote tripping mechanism by electrical acting: 24, 48 or 190 VDC
- (Optional) Anticreep device by electrical acting: 24, 48 or 190 VDC + Inductive Sensor (Included). When using the SD-BOX for UCM electronic device with Anticreep system for UCM, COIL should be 24VDC
NB. For optimal performance, it is highly recommended to use the anti-creep system in conjunction with the SD-BOX.
230 VAC - 190 VDC Rectifier (optional)
Protection plate (optional)
Test groove (optional) - Hardened groove (optional)
According to the standards:
EN 81-20 and EN 81-50.
The product has the following certifications: